STIK Instrument Equipment (Shanghai) Co., Ltd.
Product Center
GAS Series

Girder safety monitoring: The girder position safety monitoring system monitors the safety position of the girder from time to time after sterilization.
Display temperature accuracy: 0.1 degrees
Inner liner polishing: Inner liner atomizing polishing, reduce bacterial adhesion area, prevent dirt residue, convenient for users to clean and maintain
Dry burning protection: double overtemperature protection, effectively prevent dry burning
Water temperature sensor: The standard PT1000 water temperature sensor monitors the surface temperature of the heating tube to protect dry burning

Technical Specifications

Pressure interlocking mechanism
- Boot, sterilization start, the sterilization process of the micro position switch real-time monitoring of the location of the chain mechanism, once there is an abnormal automatic alarm stop, to ensure safety
- The closed status of the lock girder is monitored by real-time position sensors. After sterilization, the temperature in the chamber is below 95 ° C, and the opening temperature can be arbitrarily set.
- Double overtemperature protection
- Double limit protection
- Heating tube to prevent dry burning - with hardware and software 3 protection, according to the water temperature rise rate to protect the dry burning outside, the standard PT1000 water temperature sensor accurately control the surface temperature of the heating tube to prevent dry burning damage, while the standard liquid expansion overtemperature protection protector, resulting in direct dry burning break protection
- Automatic intelligent control system


1. External removable pressure gauge for easy verification
2. USB as standard
3. peculiarity
- Sterilization temperature can be set up to 138 degrees
- PT1000 sensor, more accurate temperature control, display accuracy of 0.1 degrees
- Configurable negative pressure range -0.1-0.5 pressure gauge, overcurrent, short circuit protection system.
- Standard hardware and software dual function to prevent dry burning, overtemperature protection system, overpressure protection safety valve.
- Open cover to stop heating function
- After the sterilization is completed, the exhaust valve can be set at the ten-stage exhaust speed.
--Freertos embedded operating system
- Standard USB flash drive real-time data recording function
- With F0 value test function
- Automatic fault monitoring, alarm and recording function (optional printer required), anti-burn safety protection.
- Automatic detection of cold air emissions to ensure pure steam sterilization
- Boiling point temperature can be set according to altitude
- The exhaust temperature can be adjusted within the boiling point temperature plus 0~25 degrees
- Dual temperature sensors that can detect air and water temperature for safer use.
- The tank body is reserved for verification holes to verify the connection
- Mechanical pressure interlocking device closed cover inspection system
- Overcurrent protection device

 

ModelGAS-54GAS-78
Volume (L)5478
Inner liner polishingSurface atomization polishingSurface atomization polishing
Liner thickness (mm)2.0 2.0 
Display accuracy (° C)0.10.1
Sterilization maximum setting temperature (℃)138138
Sterilization range (℃)105~138
Set timeSterilization, melting: 0 min ~9999 min
Program functionSterilization and liquid sterilization function
Pressure display range-0.1~0.5mpa
Exhaust mode10 exhaust
Safety devicePressure relief valve, prevent dry burning, door lock safety interlocking device, cavity cover closing detection system, overpressure detection, overtemperature detection
Maximum design pressure0.28Mpa
USBStandardStandard
Lid opening modeHand spin open
Ambient temperature5~45℃

Rated power

2800W3500W

Sterilized bladder size (diameter * height) mm

φ 370*520φ 370*740

Basket size (W*D*H)mm

φ 350*190*2φ 350*230*1
φ 350*350*1

Product weight

80KG85KG

Overall dimensions (W*D*H)mm

500*500*945500*500*1170

Working power supply

220V± 10%,16A,50HZ/60HZ